Short cycling of refer compressor. Sometimes short cycling occurs due to a system fault and sometimes it occurs due to a mismatch between system capacity and load cooling or heating too quickly. Outward movement of the pin compresses the spring and this then flips the contact to the close the compressor s starting circuit. Short cycling happens when the cooling cycle becomes much shorter than the usual 10 minutes causing the compressor to turn on and off more often than usual. If the oil level in the compressor crankcase of the refrigeration system is reducing within short intervals this indicates leakage or increase in consumption of lube oil due to the following reasons.
Short cycling of refrigeration compressor short cycling means the compressor is repeatedly running for a few seconds and then cutting off. Firstly don t leave it powered up in that condition it will take the compressor out. The compressor is failing to start and cutting out on the overcurrent temperature protector. Short cycling is almost always a symptom of a deeper problem in your compressed air system.
Short cycling is a symptom of a potentially wide range of causes. Plainly speaking short cycling means the constant repetition of refrigeration cycles within short intervals. Low or high supply voltage. Intermittent contact in electrical control circuit.
Suction pressure high high superheat at evaporator outlet. Improper mounting of the relay. Incorrect start or run capacitor. Reducing oil level in the compressor.
Continuous starting and stopping of the compressor is called short cycling in refrigeration system. This excessive stopping and starting adds wear on the compressor while robbing your home of its cooling comfort. While your air compressor short cycles you are paying a 20 50 premium for compressed air. Check the specifications with the compressor manufacturer.
This is probably due to the start relay and or start capacitor you mentioned one capacitor value 60 120mfd. Think of short 2 5 minute. Thermostat differential set too close. Short cycling occurs in your compressor when a mechanical failure is causing the run times to terminate prematurely and since set point has not been achieved it restarts shortly afterward thus requiring more compressor on time to compensate.
Check the arrow on the side of the relay it should be pointing up. It is important that your technician finds the root cause you need to know why and fix it.